title: "CASE STUDY: Revitalizing a Municipal Well"
description: With AirBurst, results are immediate and dramatic. The well's performance was not just restored; it was elevated to a level likely never achieved before.
image: https://airbursttechnology.com/hubfs/ABWS-rig-onsite.png
---

[Go Back Up](https://airbursttechnology.com/resources/case-study-well-rehabilitation#top)

[Skip to Content](https://airbursttechnology.com/resources/case-study-well-rehabilitation#body)

[![AB-Logo-WHT-CLR-Symbol-SML](https://airbursttechnology.com/hs-fs/hubfs/AirBurst%20Logos%20Final/AB-Logo-WHT-CLR-Symbol-SML.png?width=225&height=34&name=AB-Logo-WHT-CLR-Symbol-SML.png "AB-Logo-WHT-CLR-Symbol-SML")](https://airbursttechnology.com/)

Toggle Menu

- [Technology](https://airbursttechnology.com/technology)
  
  Toggle children for Technology
  
   Main Menu (Press to Return) 
  
  \> Technology 
  
    - [Applications](https://airbursttechnology.com/applications)
- [Licensing](https://airbursttechnology.com/airburst-technology-licensing)
- Resources
  
  Toggle children for Resources
  
   Main Menu (Press to Return) 
  
  \> Resources 
  
    - [FAQ](https://airbursttechnology.com/airburst-technology-faqs)
    - [Results + Insights](https://airbursttechnology.com/resources)
    - [Deep Education](https://airbursttechnology.com/education)
    - [Return-on-Rehab Estimator](https://ror.airbursttechnology.com)
    - [Licensee Portal](https://ls-portal.airbursttechnology.com)
- [About Us](https://airbursttechnology.com/airburst-technology-about-us)
  
  Toggle children for About Us
  
   Main Menu (Press to Return) 
  
  \> About Us 
  
    - [AirBurst® Locations](https://airbursttechnology.com/airburst-locations)
- [Contact](https://airbursttechnology.com/contact-us)

- [Easy Button](https://airbursttechnology.com/contact-us)
- Open Search
  
  Search
  
  Submit Search

# CASE STUDY: Revitalizing a Municipal Well

[Screened Well](https://airbursttechnology.com/resources/tag/screened-well) [Well Rehabilitation](https://airbursttechnology.com/resources/tag/well-rehabilitation) [Drilling Development](https://airbursttechnology.com/resources/tag/drilling-development) [Case Studies](https://airbursttechnology.com/resources/tag/case-studies) Nov 10, 2025, 9:02:03 AM [AirBurst Experts](https://airbursttechnology.com/resources/author/airburst-experts) 5 min read

![](https://airbursttechnology.com/hs-fs/hubfs/ABWS-rig-onsite.png?width=1000&name=ABWS-rig-onsite.png)

client: Municipal Utility in Central Illinois

## AirBurst Revitalizes Municipal Well by Removing Decade-Old Drilling Mud

Date of Service: August 2025

Well Type: 10” stainless steel, 0.055” slotted screen gravel pack

Depth: Approx. 300 feet

 

##### The Challenge

In Central Illinois, a 10-inch sand and gravel well drilled to a depth of 311 feet, was showing significant signs of underperformance. With a pumping rate of 300 gpm, the well had a drawdown of 33 feet, resulting in a specific capacity of just 9.09 sc. This inefficiency was a growing concern for the municipality. A well contractor was brought in to find a solution, who partnered with AirBurst Well Services to rehabilitate the well. The initial assessment suggested that the screen and gravel pack were blocked up with sediment and minerals and that the well may never have been fully developed when it was first drilled 19 years earlier.

##### **The AirBurst ****Solution:**

The AirBurst team arrived on-site on August 6, 2025, to execute a comprehensive rehabilitation plan. Using a 35-SL model (3.5" diameter) air gun with a 40ci chamber, the crew performed five passes through the 16-foot screen interval with 0.055” slot size (295' to 311'), delivering two high-pressure bursts of compressed gas (500-1,000 PSI) per foot on each pass.

Almost immediately, the return water showed a heavy brown discharge. During subsequent pumping tests between passes, it became evident that the discharge was drilling mud that had been masked by the formation for over ten years. This discovery confirmed that the well's poor performance was directly linked to a blocked screen and formation as well as incomplete development at the time of its construction. The AirBurst process was effectively breaking up and purging the restrictive mud layer from the borehole wall and surrounding gravel pack. 

##### The Results: A More Than 100% Improvement 

The results after the AirBurst procedure were immediate and dramatic. The well's performance was not just restored; it was elevated to a level likely never achieved before. By removing the mineral contamination and residual drilling mud, AirBurst successfully re-established a powerful hydraulic connection between the well and the aquifer. The specific capacity was increased by 115%, and the significant reduction in drawdown means the pump will operate more efficiently, leading to lower energy costs and reduced wear over time.

![capacity-metric-chart](https://airbursttechnology.com/hs-fs/hubfs/capacity-metric-chart.png?width=1373&height=663&name=capacity-metric-chart.png)

- ![ABWS-hose-before](https://airbursttechnology.com/hs-fs/hubfs/ABWS-hose-before.png?width=423&height=519&name=ABWS-hose-before.png)
  
  BEFORE: Removing the mineral contamination and residual drilling mud 
- ![ABWS-hose-after](https://airbursttechnology.com/hs-fs/hubfs/ABWS-hose-after.png?width=423&height=519&name=ABWS-hose-after.png)
  
  AFTER: Capacity was increased by 115% and the significant reduction in drawdown means the pump operates more efficiently.

![ABWS-tailgate-rig](https://airbursttechnology.com/hs-fs/hubfs/ABWS-tailgate-rig.png?width=463&height=508&name=ABWS-tailgate-rig.png)

the conclusion

## airburst well services:

This project demonstrates two key capabilities of AirBurst Well Services:

1. Effective Rehabilitation: AirBurst is a powerful tool for restoring performance in aging wells that have become clogged or encrusted over time.
2. Superior Well Development: The discovery and removal of decade-old drilling mud proves that many new wells are not fully developed with traditional methods. AirBurst should be considered an essential step for all newly-drilled wells to ensure that drilling fluids are completely removed and the well's maximum potential is realized from day one.

Contact AirBurst Technology today to learn how we can restore your well's performance or help in those tricky situations. For more information on how AirBurst can improve your new or existing wells, [visit www.airbursttechnology.com.](https://airbursttechnology.com/contact-us)

 

[Access Printable Version](https://airbursttechnology.com/hubfs/AirBurst%20Case%20Studies/AirBurst%20Case%20Study_Developing%20Screened%20Well%20IL_anonymized%20FINAL%209.3.25.pdf)

You May Like These

## Related Articles

![](https://airbursttechnology.com/hs-fs/hubfs/florida-drinking-water.jpg?width=700&name=florida-drinking-water.jpg)

### [CASE STUDY: Restoring a Major Florida Drinking Well](https://airbursttechnology.com/resources/case-study-restoring-a-major-florida-drinking-well)

![](https://airbursttechnology.com/hs-fs/hubfs/p.35%20Specific%20Capacity.jpg?width=700&name=p.35%20Specific%20Capacity.jpg)

### [When Should You Rehabilitate a Well? The Warning Sign Most Owners Miss Until It's Too Late](https://airbursttechnology.com/resources/when-should-you-rehabilitate-a-well-the-warning-sign-most-owners-miss-until-it-s-too-late)

![](https://airbursttechnology.com/hs-fs/hubfs/WW-Joliet-Location-sml.png?width=700&name=WW-Joliet-Location-sml.png)

### [CASE STUDY: Boosting Well Efficiency 191%](https://airbursttechnology.com/resources/revitalizing-a-critical-power-plant-well)

---

- [Technology](https://airbursttechnology.com/technology)
- [Licensing](https://airbursttechnology.com/airburst-technology-licensing)
- Resources
- [About Us](https://airbursttechnology.com/airburst-technology-about-us)
- [Contact](https://airbursttechnology.com/contact-us)

<https://www.youtube.com/watch?v=qDmDrwHfdpI> <https://www.linkedin.com/company/airburst-technology/about/> <https://www.facebook.com/airbursttechnology>

© 2026 AirBurst Technologies  •  (424) 415-8332  •  info@airbursttechnology.com

```json
{
  "@context" : "https://schema.org",
  "@type" : "BlogPosting",
  "author" : {
    "@type" : "Person",
    "name" : "AirBurst Experts",
    "url" : "https://airbursttechnology.com/resources/author/airburst-experts"
  },
  "dateModified" : "2026-09-22T19:41:13.137Z",
  "datePublished" : "2025-11-10T17:02:03.000Z",
  "headline" : "CASE STUDY: Revitalizing a Municipal Well",
  "image" : [ "https://airbursttechnology.com/hubfs/ABWS-rig-onsite.png" ],
  "mainEntityOfPage" : {
    "@id" : "https://airbursttechnology.com/resources/case-study-well-rehabilitation",
    "@type" : "WebPage"
  },
  "publisher" : {
    "@type" : "Organization",
    "logo" : {
      "@type" : "ImageObject"
    }
  }
}
```