title: "CASE STUDY: Precision Targeting Delivers 2.5x Flow in a Limestone Well"
description: AirBurst and Peerless Midwest used a pre-rehab video survey to target water-bearing fractures in an Indiana limestone well, lifting output from 145 to 362 gpm.
image: https://airbursttechnology.com/hubfs/AB-Peerless_logos.png
---

[Go Back Up](https://airbursttechnology.com/resources/case-study-precision-targeting-delivers-2.5x-the-flow-in-a-limestone-well#top)

[Skip to Content](https://airbursttechnology.com/resources/case-study-precision-targeting-delivers-2.5x-the-flow-in-a-limestone-well#body)

[![AB-Logo-WHT-CLR-Symbol-SML](https://airbursttechnology.com/hs-fs/hubfs/AirBurst%20Logos%20Final/AB-Logo-WHT-CLR-Symbol-SML.png?width=225&height=34&name=AB-Logo-WHT-CLR-Symbol-SML.png "AB-Logo-WHT-CLR-Symbol-SML")](https://airbursttechnology.com/)

Toggle Menu

- [Technology](https://airbursttechnology.com/technology)
  
  Toggle children for Technology
  
   Main Menu (Press to Return) 
  
  \> Technology 
  
    - [Applications](https://airbursttechnology.com/applications)
    - [CasingGuard™ Well Repair](https://casingguard.com)
- [Licensing](https://airbursttechnology.com/airburst-technology-licensing)
- Resources
  
  Toggle children for Resources
  
   Main Menu (Press to Return) 
  
  \> Resources 
  
    - [FAQ](https://airbursttechnology.com/airburst-technology-faqs)
    - [Results + Insights](https://airbursttechnology.com/resources)
    - [Deep Education](https://airbursttechnology.com/education)
    - [Return-on-Rehab Estimator](https://ror.airbursttechnology.com)
    - [Licensee Portal](https://ls-portal.airbursttechnology.com)
- [About Us](https://airbursttechnology.com/airburst-technology-about-us)
  
  Toggle children for About Us
  
   Main Menu (Press to Return) 
  
  \> About Us 
  
    - [AirBurst® Locations](https://airbursttechnology.com/airburst-locations)
- [Contact](https://airbursttechnology.com/contact-us)

- [Easy Button](https://airbursttechnology.com/contact-us)
- Open Search
  
  Search
  
  Submit Search

# CASE STUDY: Precision Targeting Delivers 2.5x Flow in a Limestone Well

[Open Borehole](https://airbursttechnology.com/resources/tag/open-borehole) [Well Rehabilitation](https://airbursttechnology.com/resources/tag/well-rehabilitation) [Case Studies](https://airbursttechnology.com/resources/tag/case-studies) Nov 19, 2026, 1:15:19 PM [AirBurst Experts](https://airbursttechnology.com/resources/author/airburst-experts) 5 min read

![](https://airbursttechnology.com/hs-fs/hubfs/AB-Peerless_logos.png?width=1000&name=AB-Peerless_logos.png)

<https://twitter.com/intent/tweet/?text=CASE+STUDY%3A+Precision+Targeting+Delivers+2.5x+Flow+in+a+Limestone+Well&url=https%3A%2F%2Fairbursttechnology.com%2Fresources%2Fcase-study-precision-targeting-delivers-2.5x-the-flow-in-a-limestone-well> <https://www.facebook.com/sharer/sharer.php?u=https%3A%2F%2Fairbursttechnology.com%2Fresources%2Fcase-study-precision-targeting-delivers-2.5x-the-flow-in-a-limestone-well> <https://www.linkedin.com/sharing/share-offsite/?url=https%3A%2F%2Fairbursttechnology.com%2Fresources%2Fcase-study-precision-targeting-delivers-2.5x-the-flow-in-a-limestone-well> [mailto:?subject=CASE%20STUDY%3A%20Precision%20Targeting%20Delivers%202.5x%20Flow%20in%20a%20Limestone%20Well&body=https%3A%2F%2Fairbursttechnology.com%2Fresources%2Fcase-study-precision-targeting-delivers-2.5x-the-flow-in-a-limestone-well](mailto:?subject=CASE%20STUDY%3A%20Precision%20Targeting%20Delivers%202.5x%20Flow%20in%20a%20Limestone%20Well&body=https%3A%2F%2Fairbursttechnology.com%2Fresources%2Fcase-study-precision-targeting-delivers-2.5x-the-flow-in-a-limestone-well)

## AirBurst Targets Water-Bearing Fractures to Lift a Municipal Well from 145 to 362 GPM

Client: Municipal Utility in Central Indiana

Prime Contractor: Peerless Midwest

Well: 179' deep, 8" open limestone borehole supplying municipal drinking water, cased to 54'

##### The Challenge

A municipal utility in Central Indiana relies on a 179-foot open limestone well as part of its drinking water supply. Over time, the well's output had fallen to the point that it could barely hold 145 gallons per minute. During the pre-rehabilitation pump test, the well broke suction at just over 145 gpm, with 24.2 feet of drawdown and a specific capacity of 5.98 gpm/ft. The pump simply could not be run harder without starving.

In an open limestone borehole, water does not enter evenly along the wall. It arrives through a handful of fractures and solution channels, and when those pathways plug with iron, mineral scale and biofilm, the whole well suffers. The utility brought in Peerless Midwest, who partnered with AirBurst Well Services to reopen those pathways without damaging the borehole.

##### The AirBurst Solution

![Cross-section of the limestone well showing casing, pump, the water-bearing fracture at 103 ft and the AirBurst treatment zone from 74 to 177 ft](https://airbursttechnology.com/hs-fs/hubfs/AirBurst-Indiana-Limestone-well-diagram.png?width=300&height=467&name=AirBurst-Indiana-Limestone-well-diagram.png)

Every AirBurst job starts with the well's own record. The team reviewed the downhole video survey run in late October 2019 to map the borehole before any energy went into it. The video identified the principal water-bearing fracture at 103 feet, along with softer sections of the formation where aggressive treatment could cause sloughing or instability. That map became the prescription.

The crew deployed a 2800SL AirBurst gun with an 80-cubic-inch chamber, firing compressed gas at 2,000 PSI. Working from 177 feet up to 74 feet, they delivered six bursts per foot at 20-second intervals, roughly 600 controlled pulses across the treatment zone. At the 103-foot fracture, the crew held position and worked it for a dedicated 15 minutes, driving repeated pressure waves directly into the most productive part of the aquifer connection. Treatment intensity was dialed back through the softer intervals flagged on the video.

The effect was visible at the surface. During each stage of the post-treatment pump test, the discharge ran heavy with red iron, the deposits that had been choking the fractures for years, now being pulled out of the formation and into the wellbore for removal.

##### The Results: 2.5x the Flow, +75% Specific Capacity

After AirBurst, the pump was run wide open at 362 gpm, two and a half times the rate at which the well had previously broken suction. Specific capacity climbed from 5.98 to 10.46 gpm/ft, a 75% improvement, although a true comparison is difficult to make given the extreme differences in flow rates. Because the test was limited by the pump rather than the well, the well's true post-rehab capacity may be higher still. Most importantly, after the rehab, the Peerless crew could reset the pump at 102' with confidence that the well would sustain the enhanced flow rate indefinitely.

![Pumping rate rose from 145 to 362 gpm and specific capacity from 5.98 to 10.46 gpm/ft after AirBurst](https://airbursttechnology.com/hs-fs/hubfs/AirBurst-Indiana-Limestone-results-chart-dark.png?width=975&height=390&name=AirBurst-Indiana-Limestone-results-chart-dark.png)

| Performance Metric | Before AirBurst | After AirBurst | Change |
| --- | --- | --- | --- |
| Pumping Rate | 145 gpm | 362 gpm | **+150%** |
| Specific Capacity | 5.98 gpm/ft | 10.46 gpm/ft | **+75%** |
| Drawdown | 24.2 ft | 34.6 ft | — |
| Static Water Level | 41.4 ft | 41.1 ft | — |
| Pumping Water Level | 67.9 ft | 76.0 ft | — |

##### Why Precision Matters in Limestone

Limestone wells reward accuracy. Spread energy evenly from top to bottom and much of it is wasted on tight rock, while soft zones can be destabilized. AirBurst combines two things in one tool:

- **Energy:** high-pressure pulses powerful enough to reach deep into fractures and break up hardened iron, scale and biofilm.
- **Control:** the operator knows exactly where the gun is and sets firing rate and pressure from the surface, foot by foot, so the crew can concentrate on the water-bearing fractures and ease off where the video shows weak rock.

**No other air impulse tool offers that combination of energy and control.** In this well, it meant the 103-foot fracture got sustained, focused treatment while the borehole stayed intact.

##### Conclusion

By treating the well according to its own map, AirBurst and Peerless Midwest turned a well that could not sustain 145 gpm into one producing 362 gpm, with no chemicals and no damage to the formation. For utilities with fractured rock wells, it shows the value of pairing a pre-rehab video survey with a tool precise enough to act on it.

For more information on how AirBurst can restore wells in limestone and other fractured-rock formations, contact us at [www.airbursttechnology.com](https://airbursttechnology.com/contact-us). To learn more about Peerless Midwest's well and pump services, visit [www.peerlessmidwest.com](https://www.peerlessmidwest.com/).

 

[Access Printable Version](https://airbursttechnology.com/hubfs/AirBurst-Case-Study_Indiana-Limestone_vF.pdf)

## AirBurst Experts

You May Like These

## Related Articles

![](https://airbursttechnology.com/hs-fs/hubfs/ABWS-rig-onsite.png?width=700&name=ABWS-rig-onsite.png)

### [CASE STUDY: Revitalizing a Municipal Well](https://airbursttechnology.com/resources/case-study-well-rehabilitation)

![](https://airbursttechnology.com/hs-fs/hubfs/Figure%202.3.jpg?width=700&name=Figure%202.3.jpg)

### [How to Run a Pump Test You Can Actually Trust: Step-Drawdown, Constant-Rate, and the Mistakes That Ruin Both](https://airbursttechnology.com/resources/how-to-run-a-pump-test-you-can-actually-trust-step-drawdown-constant-rate-and-the-mistakes-that-ruin-both)

### [CASE STUDY: Restoring a Major Florida Drinking Well](https://airbursttechnology.com/resources/case-study-restoring-a-major-florida-drinking-well)

---

- [Technology](https://airbursttechnology.com/technology)
- [Licensing](https://airbursttechnology.com/airburst-technology-licensing)
- Resources
- [About Us](https://airbursttechnology.com/airburst-technology-about-us)
- [Contact](https://airbursttechnology.com/contact-us)

<https://www.youtube.com/watch?v=qDmDrwHfdpI> <https://www.linkedin.com/company/airburst-technology/about/> <https://www.facebook.com/airbursttechnology>

© 2026 AirBurst Technologies  •  (424) 415-8332  •  info@airbursttechnology.com

```json
{
  "@context" : "https://schema.org",
  "@type" : "BlogPosting",
  "author" : {
    "@type" : "Person",
    "name" : "AirBurst Experts",
    "url" : "https://airbursttechnology.com/resources/author/airburst-experts"
  },
  "dateModified" : "2026-11-19T20:28:37.872Z",
  "datePublished" : "2026-11-19T20:15:19.000Z",
  "headline" : "CASE STUDY: Precision Targeting Delivers 2.5x Flow in a Limestone Well",
  "image" : [ "https://airbursttechnology.com/hubfs/AB-Peerless_logos.png" ],
  "mainEntityOfPage" : {
    "@id" : "https://airbursttechnology.com/resources/case-study-precision-targeting-delivers-2.5x-the-flow-in-a-limestone-well",
    "@type" : "WebPage"
  },
  "publisher" : {
    "@type" : "Organization",
    "logo" : {
      "@type" : "ImageObject"
    }
  }
}
```